spectra max i3x. 모든 제품. spectra max i3x

 
 모든 제품spectra max i3x  Wokingham, Berkshire RG41 5TS United Kingdom

SpectraMax iD5:Fluorescence was quantified using a microplate reader (SpectraMax i3x, Molecular Devices, CA, USA) with an excitation and emission wavelength being 365 nm and 450 nm, respectively (Jian et al. The dual auto injector module. The SpectraMax® i3 Platform from Molecular Devices® is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. If desired, a high-range standard curve may be prepared from 1 ng/mL to 1 μg/mL, or a low-range standard curve may be prepared from 25 pg/mL to 25 ng/mL. Supplier: Molecular Devices. The SpectraMax® i3x Multi-Mode Detection Platform measures spectral-based absorbance, fluorescence, and luminescence with the added. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,The SpectraMax® M5 utilizes a single monochromator design for UV/VIS Absorbance, allowing the user to maximize sensitivity and tunability, and also uses patented PathCheck® Pathlength Measurement Technology:. It allows you to explore cellular pathways and protein activation and expression in one system. Afterwards, 25 μL SpectraMax Glo Steady-Luc working solution was added to the wells containing luciferase and controls. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader applications, protecting your initial investment. 2 in. The heating element design of the category 1 microplate readers, such as the SpectraMax i3x Multi-Mode Microplate Reader, applies a dual area sensor for temperature control. Multiple automated tests are provided including: • Linearity • Precision • Accuracy • Dynamic range • Alignment • Signal to noise • Signal to background • Filter checks. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. Designed specifically for the SpectraMax® i3 Multi-Mode Detection Platform, the field-upgradeable SpectraMax® MiniMax™ 300 Imaging Cytometer enables quick inspection of cells and provides insight into phenotypic changes that are important for understanding cytotoxicity, cell proliferation, and protein expression. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. SpectraMax i3x and Paradigm readers require the FP-FLUO. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. SpectraMax® iD3/iD5. 306 plate air cal. StainFree Cell Detection Algorithm. Auto PMT Challenge: A standard Photomultiplier Tube (PMT) or detector limits the dynamic range of your instrument. When used in combination with the SpectraMax Injector Cartridge, this system enables a wealth of flash type luminescence applications including reporter gene and other assays with exceptional sensitivity and dynamic range. Expand your lab’s capabilities to include flash applications such as dual luciferase and. SpectraMax® i3x Multi-Mode Detection Platform, Molecular Devices. ) deep, preferably with access on all sides. The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. Dual auto injector cartridges for the SpectraMax® i3x Multi-Mode Microplate Detection Platform allows you to expand your research capabilities to include flash based applications, including dual luciferase and ATP assays. The SpectraMax i3x reader is engineered to perform with Spectral Fusion Illumination for increased sensitivity across the entire wavelength range, and a cooled photomultiplier tube (PMT) for improved detection in extremely low light. Prepare your iD series instrument for shipment. Eliminate time-dependent substrate addition steps. Learn how you can perform flash-based applications, such as dual luciferase and ATP assays, with high precision and accuracy using this cartridge. 5 decades, with sensitive detection of cells. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. Using the SpectraMax i3x reader, the preconfigured SpectraMax Glo Steady-Luc Reporter assay protocol in SoftMax Pro Software was used to measure luminescence. The MiniMax cytometer with SoftMax® Pro Software can be used to image and analyze a variety of cells. i3x. The SpectraMax ® i3x reader provides the. After incubation at 37 °C and 5% CO 2 for 20 min, fluorescence images were taken using Spectra Max i3x with MiniMax 300 Imaging Cytometer (Molecular Devices, San Jose, CA) using the setup of excitation and emission provided in the SoftMax Pro 7. Figure 2-23: Bottle holder To install the bottle holder: 1. The SpectraMax i3 also allows the user to identify antibodies during Elisa Assays. 2. We would like to show you a description here but the site won’t allow us. Example: [Drawer]. Learn how you can perform flash-based applications, such as dual luciferase and ATP assays, with high precision and accuracy using this cartridge. Spectranet customer portalPage 38 SpectraMax iD3 Multi-Mode Microplate Reader User Guide Bottle Holder The bottle holder is mounted on two knobs for ease of installation, cleaning, and replacement. Products : SpectraMax i3x reader, SpectraMax iD5 reader, SpectraMax iD3 reader, General, FilterMax F5 reader, SpectraMax ABS reader, SpectraMax L reader, SpectraMax M5/M5e reader This page contains the table of contents of resources available for the SpectraMax Microplate Reader Suite of Products. Spectral Fusion Illumination is a powerful combination of Xenon flash lamp and LEDs that provides unmatched signal strengthSpectraMaxABSInstrumentInstallationGuide 4 5065391A ComputerIntegration EachMolecularDevicesmicroplatereaderisshippedwithalicensekeyfortheSoftMax®ProSpectraMax iD5 reader. How to properly unlock iD series instrument. Controls containing all reaction components with either DI . Measured using the SpectraMax DuoLuc Reporter Assay Kit on the SpectraMax i3x microplate reader. AlphaScreen and AlphaLisa detection using a 680 nm excitation laser diode and a 570/100 nm emission filter. It allows you to explore cellular . ; India imports most of its Spectramax from United States, China and Austria and is the largest importer of Spectramax in the World. VAL014, right table) assays on the SpectraMax i3x reader are shown below. Increased fluorescence performance. Capture Flash Assays with Ease. ZERO BIAS - scores, article reviews, protocol conditions and more. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. Overview of SpectraMax MiniMax 300 Imaging Cytometer. 4 μM), prepared as described in section 2. Price from $9. Time-. Apoptosis was measured by the Annexin V-FITC/PI Apoptosis Detection Kit. SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual 1-3 Introduction General Overview The SPECTRAmax ® 340PC incorporates a holographic grating monochromator which allows you to specify a precise wavelength, from 340 nm to 850 nm, for the absorbance maximum of your sample. The PMT gain can be set to manual, high, medium, low, or automatic (Figure 3A). With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. Flow cytometry was used to measure ROS concentrations, based on fluorescence intensity (FL-1, 530 nm) of 10,000 cells. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. We would like to show you a description here but the site won’t allow us. 313 reference gain check fail. A: percent GFP-positive cells calculated using the classification feature in the software. Fluorescence emission spectra were collected on an ELISA molecular system (Spectra Max i3x). For more detailed information and technical support of Life Technologies assays, please call 1-800-955-6288 and enter extension 40266 or email drugdiscoverytech@lifetech. Microplate assays were performed on a multimode microplate detector (Molecular Devices Spectra Max i3x). Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. , 2014; Xiong et al. Time-resolved fluorescence was measured on the SpectraMax Multi-Mode Microplate Readers (see Table 2 for instrument settings). Explore more about the SpectraMax i3x Multi-Mode Plate Reader, a user-upgradeable detection modules allow you to expand the capabilities of your microplate reader when your research requires it. The SpectraMax i3x Injector Cartridge with SmartInject Technology is a data sheet that describes the features and benefits of this innovative accessory for the SpectraMax i3x Multi-Mode Detection Platform. SpectraMax i3x Multi-Mode Detection Platform User Guide. Our microplate readers and software are the industry’s most cited and have empowered life science researchers to advance protein and cell biology. Eliminate time-dependent substrate addition steps. Microplate optimization should be performed the first time the assay is run, and subsequently for . Animal imaging assay was performed on a IVIS R Lumina Series III small animal optical system. 10, and 0. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. This application note describes the use of the SPECTRAmax ® GEMINI XS from Molecular Devices to study the performance of the LIVE/DEAD ® Viability/Cytoxicity Assay Kit for animal cells. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. flThe SpectraMax M2 and M2e systems provide the multi detection microplate readers with dualmonochromators, dual-mode cuvette ports, with top & bottom reading. The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel detection capabilities without the need for service. 2. 0´ 104 6. Also review the Maintenance and Troubleshooting chapter of the user guide for your model plate reader. 価格、見積もり、お近くの販売店を. Example: [Drawer]. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. TP medium was used as a blank and its fluorescence intensity was subtracted from that of mCherry or from chlorophyll auto-fluorescence intensity. Bioz Stars score: 98/100, based on 1 PubMed citations. The chamber. 315 can't find zero order. SpectraMaxi3xMulti-ModeDetectionPlatformUserGuide 72 5039228D. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Page 9 Installing and Setting Up the SpectraMax MiniMax Imaging Cytometer Attaching the Imaging Cytometer to the Microplate Reader Attaching the SpectraMax MiniMax Imaging Cytometer to the SpectraMax i3x Instrument requires a work area that is approximately 130 cm (51. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Absorbance Detection Cartridges combine scanning and broad spectrum wavelength range to address a variety of nucleic acids, proteins, ELISAs and immunoassays found in the laboratory. The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel. The Molecular Devices SpectraMax i3x Microplate Reader is a multi-mode microplate reader, able to measure UV/vis, fluorescence and luminescence. . CRITICAL STEP Avoid air bubbles; reverse pipetting the luciferase reagent into the plate is a good way to achieve this. • SpectraMax i3x • Onboard luminescence • Detection cartridge (LUM 96) • SpectraMax iD5 • SpectraMax L • SpectraMax M5e • SpectraMax Mini. Multimode Reader Comparison Chart. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. Examples: fiPress carefully to engage,fl fiDo not press down. HTRF IP standard curve. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. for the SpectraMax M3/M4 and FlexStation® 3 Multi-Mode Microplate Readers. 2/5 apart, not needed o Otherwise, ensure cutoff is 10nm less than desired emission wavelength. The SpectraMax® i3x Multi-Mode Microplate Reader with the SpectraMax® MiniMax™ 300 Imaging Cytometer is equipped with transmitted light (TL), green fluorescence (Ex/Em: 460/541), and red (625/713) fluorescence channels. SpectraMax i3Instrumenttovisuallyinspectyoursampleandtoruncell-basedassaysat cellularorwhole-cellresolution. The SpectraMax® M3 Multi-Mode Microplate Reader features dual monochromatic optics to allow the widest range of applications to be utilized for bioresearch procedures, without the need to change filters. Find regional support. Enzyme Activation Analysis;. SpectraMax® i3x Multi-Mode Microplate Reader with MiniMax™ imaging cytometer Integrated multi-mode microplate reader and imaging system • Ideal for cell counting, label-free imaging, and cell proliferation • Western blot, imaging, and injectors on one configurable microplate reader • Stain free, automated cell countingusing the SpectraMax DuoLuc Reporter Assay Kit on the SpectraMax i3x microplate reader. Description 1. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. Absorbance Detection Cartridges combine scanning and broad spectrum wavelength range to address a variety of nucleic acids, proteins, ELISAs and immunoassays found in the laboratory. Plate chamber design of the SpectraMax category 1 microplate readers. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. Features technology from the SpectraMax i3x and MiniMax 300 Imaging Cytometer. , 2021). Videos & Webinars SpectraMax i3x - Detection Module ChangeSpectraMax M2 & SpectraMax M2e Multi-mode Plate Readers Operator’s Manual — 0112-0115 Rev. Fluorescence intensity was measured using a Spectramax i3x plate reader (Molecular Devices) with excitation at 575 nm (bandwidth 9 nm) and emission at 608 nm (bandwidth 15 nm). Products : FlexStation 3 reader, SpectraMax M5/M5e reader, SpectraMax M2/M2e reader. 99(图一)。After incubation at room temperature for one hour in the dark, we measured the fluorescence intensity using a SpectraMax i3x (Molecular Devices, CA, USA), with excitation at 350 nm and dual emissions at 435 nm and 490 nm. SpectraMax i3x plate reader (Molecular Device, contact supplier directly) Vacuum pump system (e. The SpectraMax i3x Multi-Mode Microplate Reader has been validated for use with the ValitaTiter and ValitaTiter Plus assays. Published Dec 16, 2020 | Updated Oct 10, 2023. Image analysis provides accurate data. Microplate reader assays requiring infrared (IR) or red-shifted. 1) Select the correct plate and the wells that you want to measure. The SpectraMax DuoLuc Reporter Assay has been performance optimized on the SpectraMax i3x reader with Injector Cartridge. Structured Review. Unpacking and setting up the instrument includes the following procedures: • Unpacking the instrument and saving the original packaging. Then, the cell area was calculated for each. View online or download 1 Manuals for Molecular Devices SpectraMax i3x. It allows you to explore cellular pathways and protein activation and expression in one system. Also review the Maintenance and Troubleshooting chapter of the user guide for your model plate reader. Figure 1. Home > Search Results > Danaher Inc > spectramax i3x. 0112-0115G October2018 SpectraMax®M3 SpectraMax®M4 SpectraMax®M5 SpectraMax®M5e Multi-ModeMicroplateReaders UserGuideSpectraMax® Microplate Readers and SoftMax® Pro Software. The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. The SpectraMax i3x from Molecular Devices is a multi-mode plate reader that can measure spectral-based absorbence and luminescence. SpectraMaxi3xMulti-ModeDetectionPlatformUserGuide 72 5039228D. The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel. no. 0´ 104 8. In addition, Image J was used to quantify the. Multimode Reader Comparison Chart. As. Donor emission at 616 nm is used as an internal reference, while acceptor emission at 665 nm. The SpectraMax i3x Injector Cartridge with SmartInject Technology is a data sheet that describes the features and benefits of this innovative accessory for the SpectraMax i3x Multi-Mode Detection Platform. spectramax i3x (Danaher Inc)The fluorescence emission intensity spectra were recorded using a microplate reader (Spectra Max® i3x, Molecular Devices, LLC. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,Danaher Inc spectramax i3x Spectramax I3x, supplied by Danaher Inc, used in various techniques. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. Order Now. The possibility of user upgrading the system with an application cartridge and an imaging cytometer makes this device the most flexible microplate. 2 in. SpectraMax i3x, onboard luminescence 121. The dynamic range of the assay is about 3. The SpectraMax i3x Multi-mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with added functaionlity of modular upgrades for Western Blot, Imaging, and Fast Kinetics with Injectors. Be Future Ready with the SpectraMax i3x Multi-Mode Detection Platform. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. The SpectraMax i3x microplate reader measures absorbance, luminescence and fluorescence as standard, and provides the flexibility to add novel detection capabilities without the need for service. Absorbance: For wavelengths in the visible range, 340 nm and above, clear polystyrene plates are recommended. The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. The SpectraMax i3x Multi-mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with added functaionlity of modular upgrades for Western Blot, Imaging, and Fast Kinetics with Injectors. This assay uses two fluorescent dyes, calcein AM (cal AM) and ethidium. Detection cartridge modularity allows for easy addition of new read modes within minutes without. The SpectraMax i3x’s user-upgradeable application modules will future-proof your research to include most assay capabilities of the SpectraMax iD3 and iD5 readers, as well as additional capabilities such as imaging. Register to download your free eBook today. The protocols are also available on the SoftMax Pro Software protocol sharing. Formicro-volumemeasurements,theinstrumentsupportsSpectraDrop24-wellSpectraMax i3 Install Guide; SpectraMax i3; SpectraMax i3x; SpectraMax iD3; SpectraMax iD5; SpectraMax Mini; SpectraMax Mini Install Guide; SpectraMax Mini Reader Plug-In Download Page (required for SoftMax Pro 7. SpectraMax i3x Multi-Mode Microplate Reader; SpectraMax MiniMax 300 Imaging Cytometer *Here, the NucView 488 with DMSO formulation was used. Find regional support. 2 x 10-14. Next, an AlphaLISA assay was developed to detect levels of pro-inflammatory factors produced by endothelial cells in response to TNF-alpha stimulation. Explore a wealth of applications with the future-ready SpectraMax i3x. 58% for the detection module and 2. +44 118 944 8000. The SpectraMax M5e Multi-Mode Microplate Reader features a triple-mode cuvette port, temperature control, microplate shaking, and the industry leading SoftMax Pro. ISM Equipment Classification (Group 1, Class A) This equipment is. Located at the right front of the SpectraMax Plus 384, the cuvette chamber has a lid that lifts up, allowing you to insert or remove a cuvette. Table 3 Optimal instrument settings for Valita Titer Plus assay Fluorescence Polarization measurement on Molecular Devices microplate readers. Immunofluorescence StainingAfter cooled down to room temperature, the concentrations of the solution were measured by microplate reader (Spectra Max i3x) at 490 nm (Kagi and Schaffer, 1988). NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. 1 1 10 100 e e e e e e eThe SpectraMax MiniMax 300 Imaging Cytometer option can be added at any time to the SpectraMax i3x System, providing an expandable platform that evolves with your changing needs. Quantification of NETs was performed with the SpectraMax i3x microplate-reader (Molecular Devices, United Kingdom). Its dual light sources, a xenon lamp and LEDs, illuminates samples with incomparable signal strength and superior sensitivity. 0112-0115J 9 Chapter1:Introduction TheSpectraMax®M3Multi-ModeMicroplateReader,SpectraMax®M4Multi-ModeMicroplate Reader,SpectraMax®M5Multi-ModeMicroplateReader,andSpectraMax®M5eMulti-ModeSpectraMax MiniMax 300 イメージングサイトメーター は、研究室でのアップグレードが可能なSpectraMax i3xシステム専用のオプションで、ユーザーは複雑なイメージングシステムに投資することなく、細胞増殖を解析できます。SPECTRAmax PLUS 384 Microplate Spectrophotometer Operator’s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax PLUS 384 control panel are shown in boxed Helvetica type. Research Article Streptococcus lutetiensis Induces Autophagy via Oxidative Stress in Bovine Mammary Epithelial Cells Peng Chen ,1 Jingyue Yang,1 Naiwen Wu,1 Bo Han,1 John P. The SpectraMax i3 is specifically used in this lab for BCA assays and Elisa Assays. The plate was shaken and incubated in the dark for 10 minutes. 0. The SpectraMax® Paradigm® Multi-Mode Microplate Reader measures absorbance, fluorescence, time-resolved fluorescence (including HTRF), fluorescence polarization, AlphaScreen®, AlphaLISA®, and luminescence assays for up to 1536-well plates. Spectral Fusion Illumination is a powerful combination of Xenon flash lamp and LEDs that provides unmatched signal strengthTNF-alpha quantification down to low picomolar levels on the SpectraMax Paradigm Platform. 2. Spectral Fusion Illumination is a powerful combination of Xenon flash lamp and LEDs that provides unmatched signal strengthThe SpectraMax i3x reader grows with you as your research areas expand. Detection of pro-inflammatory factors. 312 gain calibration failed. 313 reference gain check fail. flValitaTiter (i3x i3) ValitaTiter (iD5) ValitaTiter (M5 M5e Flex3) ValitaTiter (Paradigm) ValitaTiter (FilterMax F5) Assay-Specific. 001 0. Ferguson, Ph. The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. 314 low lamp level warning. The LDH activity in the cultural media was measured based on the reaction between LDH and lactic acid, which led to the generation of pyruvic acid, and pyruvic acid could become brown in alkaline environments with 2,4. detection cartridge LUM96: 59. HeLa cells were plated at 15,000 cells per well in 100 µL of medium in a 96-well black, clear-bottom microplate. 5577 Web: Email: [email protected] SpectraTest® Validation Plates are valuable tools for verifying that absorbance-, fluorescence-, and luminescence-capable microplate readers are operating correctly for GMP and GLP laboratories. SpectraDrop Abs Protein Quant (i3-i3x)Molecular Devices SpectraMax i3x Multi-Mode Detection Platform. Kastelic,2 and Jian Gao 1 1Department of Clinical Veterinary Medicine, College of Veterinary Medicine, China Agricultural University, Beijing 100193, China. Detection of pro-inflammatory factors. Published Dec 16, 2020 | Updated Dec 16, 2020. 3 In this application note we demonstrate a linear dynamic range of 6 decades for recombinant firefly and Renilla luciferases, as well as linear detection of luciferase-transfected. SoftMax Pro Software is an industry-leading acquisition and analysis software with over 160 ready-to-run protocols, powerful data analysis, and a range of data output options. 1. The SpectraMax i3 Platform's base system features an integrated optical system enabling top and bottom reads for 6 - 384 well microplates and launches with three broad detection modes: luminescence, absorbance, and fluorescence. Robust,. Contact Local Team. spectramax i3x (Danaher Inc)The SpectraMax® i3x multi-mode microplate reader is a configurable, versatile microplate reader that evolves with your future needs and allows you to investigate every aspect of a cellular pathway. Using the SpectraMax i3x reader, the preconfigured SpectraMax Glo Steady-Luc Reporter assay protocol in SoftMax Pro Software was used to measure luminescence. The calculated LOQ values were 0. , Fisher Scienti fi c, cat. HTRF IP1 standard curve measured on the SpectraMax i3x (green circles) and SpectraMax iD5 (red circles). An MPO assay has been performed to quantify the inflammation reduced by the GAR-PLGA-ES100 NPs in the inflamed cells . 1. Molecular Devices Corporation. Also refer to this Multimode Reader Comparison Chart. Replicate values were averaged and imported into Design-Expert 8. The standard solutions (0. 1 mg/mL density of resazurin, protected of the light, incubated for 1 h at room temperature. ; Page 2 Molecular Devices equipment, software, reagents, and consumables. ZERO BIAS - scores, article reviews, protocol conditions and more. Explore a wealth of applications with the future-ready SpectraMax i3x. 0´ 104 1. Additionally, user-installable options allow the SpectraMax i3 System to grow with your changing application needs to fulfill and go beyond the standard reader applications, protecting your intial investment. 모든 제품. The chamber. Prime function 20 amol. Multimode Readers Comparison Chart. Settings not required by a reader are indicated by ‘---’. Features. 01 0. 04, 0. Shake intensity. The SpectraMax i3x reader grows with you as you continue to advance your research, enabling you to unravel the mysteries of science by exploring cellular pathways and protein activation and expression in one system. Turbidity measurements were performed with a Spectra Max® i3x microplate reader to study the effect of oxidation on the kinetics of sFN formation. KEY FEATURES • Combine cellular imaging and microplate assays into a workflow • Eliminate cell staining for cell counting and confluency with StainFree Technology The SpectraMax i3x reader measures spectral-based absorbance, fluorescence, and luminescence with the added functionality of modular upgrades for western blot, imaging, and fast kinetics with injectors. Myeloperoxidase (MPO) Assay. The SpectraMax® i3 Platform from Molecular Devices® is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. Prepare your i3/i3x instrument for shipment. Prismatic colour and motion for everyone. 吸収度マイクロプレートリーダー SpectraMax® Mini. 5 µL anti-cAMP-Cryptate. Find our technical support information along with contact details. Data from Analyst®, and FLIPR® systems can also be easily imported and analyzed. Because a PMT needs to be set to a specified gain to reach a specific sensitivity,SpectraMax M3 Plate Read, Plate Map, Data Analysis and Export Setup pg. 0´ 105 dsD NA (p g/ wel ) R F USpectraMax Glo Steady-Luc 工作液都加 入到微孔板后,震荡摇匀并避光放置 10 min。使用 SpectraMax Glo Steady-Luc Reporter 内置的 SpectraMax Glo Steady- Luc Reporter 实验模板设定程序并通过 SpectraMax i3x 读板机检测发光。检测结 束后,模板会根据数据自动生成一条曲 线。SpectraMax MiniMax 300 细胞成像系统 为 SpectraMax i3x 多功能微孔板检测平台而打造! • • • • 主要特点 系统全面兼容细胞成像 及微孔板检测技术 独特无标记分析技术无需 对细胞染色即可进行细胞 计数和贴壁度的计算 具有多种检测功能可对 细胞活力及毒性进行全. User-upgradeable detection modules allow you to expand the capabilities. If you do not have an iLab account you must first make one: SpectraMax iD3 User Guide provides detailed instructions on how to operate, maintain, and troubleshoot the SpectraMax iD3 Multi-Mode Microplate Reader, a versatile instrument that measures absorbance, fluorescence, and luminescence. SpectraMax® i3x 多功能读板机配置 SpectraMax® MiniMax™ 300 细胞计数 仪,具有 transmitted light (TL),绿色 (Ex / Em: 460 / 541) 和红色 (Ex / Em: 625 / 713) 荧光通道。MiniMax 细胞计数仪的 SoftMax® Pro 软件可以用来获得各种细 胞的图像并进行分析。本说. INTRODUCTION The SpectraMax M2 and SpectraMax M2e Multidetection Readers are monochromator based microplate readers that have 6well to 38 4well microplate reading capability as wellSpectraMax i3x The SpectraMax i3x from Molecular Devices is a multi-mode detection system that evolves with your future needs and offers an unlimited breadth of application possibilities. Cell viability was calculated as average percent of the OD reading relative to that of control group, which was normalized to 100%. g. The turbidity. The cell imaging was captured on Zeiss LSM 980 confocal microscopy. As per Volza’s India Import data, Spectramax import shipments in India stood at 365, imported by 145 India Importers from 28 Suppliers. Prime function 20 amol. The SpectraMax i3x reader allows you to unravel the mysteries of science by exploring cellular pathways and protein activation and expression in one system. The UV-Vis spectroscopy was measured on a TU-1900Beijing PuXi instrument. The SpectraMax i2X is used for cell migration, cell. Concentrating the excitation light on the sample through label specific optics, high levels of sensitivity and performance are reached. 200-800 nm using Spectra Max i3X microplate reader. See SpectraMax® Microplate Reader User Manual Download Page. Microplate readers, multi-mode, SpectraMax® i3x. The corrected absorbance is within 5% of the. Easily upgrade or switch between detection modes with user-exchangeable modules – just open the drawer and insert the module you want. 1. Figure 4. 635. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. The drawing shows a standard microplate of 15 mm height covered with a lid. Molecular Devices’ SpectraMax i3x Multi-Mode Microplate Reader and Thermo Fisher Scientific’s Varioskan LUX reader also perform multiplexing. This technical note demonstrates validation of the SpectraMax® i3x Multi-Mode Microplate Reader for NanoBRET™ assays. Patented user-exchangeable cartridge design expands the system's detection capability making it. Prepare your i3/i3x instrument for shipment. Auto PMT Challenge: A standard Photomultiplier Tube (PMT) or detector limits the dynamic range of your instrument. If desired, a high-range standard curve may be prepared from 1 ng/mL to 1 μg/mL, or a low-range standard curve may be prepared from 25 pg/mL to 25 ng/mL. Patented user-exchangeable cartridge design expands the system's detection capability making it. Fluorescent Polarization: Solid black plates, as above. Reporter Assay. Downloads. **On the SpectraMax iD3/iD5 readers only All graphs are for illustrative purposes only. Time Resolved Fluorescence: Solid white plates for top reads and white plates with clear bottoms for bottom reads. Spectranet customer portal The SpectraMax ® i3x Platform from Molecular Devices is a multi-mode microplate reader that evolves with your future needs and offers an unlimited breadth of application possibilities. 0 mm hex key to remove the six blue retaining screws that secure the transport bracket (B) to the instrument. Superior flexibility The SpectraMax i3 Multi-Mode Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. This eBook shows how to see more and do more with an imaging cytometer that enables rapid imaging and cell analysis. The SpectraMax® Paradigm® Multi-Mode Microplate Reader measures absorbance, fluorescence, time-resolved fluorescence (including HTRF), fluorescence polarization, AlphaScreen®, AlphaLISA®, and luminescence assays for up to 1536-well plates. Ideal for a wide range of applications, including Western Blot analysis, this SpectraMax i3x includes the additional MiniMax 3000 Imaging Cytometer module for advanced cell imaging. Find regional support. 0´ 104 4. i3x. NORTH AMERICA +1 800-635-5577 Mon to Fri 7am - 5pm Pacific Time. 316 grating motor driver faulty. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. 4. Italic and boldface type are used for emphasis. The chamber. The FRET ratio is defined as the relative fluorescence intensity of an acceptor normalized to the total fluorescence intensity. The SpectraMax i3x reader provides theAbsorption was measured at 490 nm by utilizing a Spectra max i3x Multimode microplate reader (Molecular Devices). The SpectraMax i3x reader has variable bandwidth for fluorescence and luminescence, and you are able to choose either 9nm or 15 nm for excitation and either 15 nm or 25 nm for emission. HTRF is a proprietary time-resolved fluoresce nce technology that overcomesThe SpectraMax i3x reader features a cooled photomultiplier tube (PMT) for low background noise in luminescence. This eBook shows how to see more and do more with an imaging cytometer that enables rapid imaging and cell analysis. It also integrates with the. Accordingly, we calculated the Laurdan generalized polarization (GP) using the formula GP = (I 435 − I 490)/(I 435 +. Find regional support. The SpectraMax® i3x Multi-Mode microplate reader measures spectral-based Absorbance, Fluorescence, and Luminescence with the added functionality of modular upgrades for Western Blot, Imaging, and Fast Kinetics with Injectors. Preconfigured protocols and custom assay workflows simplify microplate data acquisition and analysis. 2) Add in your protocol in Method Editor the Fluorescence Polarization strip. 2. Unlock your i3/i3x instrument after shipment. 4. 1. Features. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. Nuclear Receptor. Briefly, after exposed to ZnO/GO and Cd, cells were collected and washed with ice-cold PBS twice and then re-suspended in 200 μL binding buffer. Italic and boldface type are used for emphasis. Superior flexibility The SpectraMax i3 Multi-Mode Platform comes with standard spectral absorbance, fluorescence, and luminescence detection. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable. The chemical reduction of resazurin was evaluated incubating each well of the microtiter plate with 10 μL (10% of final well volume) of 0. 0200-7029 Wavelength range (LUM): Visible to 650 nm Dead volume: < 10 µL with Reverse . Microplate and read height should be optimized for each new lot of microplates or assay volume used (use the Show Pre-Read Optimization options in the instrument settings in SoftMax Pro Software). The MPO assay was conducted according to the. The SpectraMax i3x reader allows you to unravel the mysteries of science by exploring cellular pathways and protein activation and expression in one system. 2 only) SpectraMax M-series Microplate readers. The ScanLater Western Blot Detection Cartridge is a user-installable option for the SpectraMax i3, i3x and Paradigm Multi-Mode Readers. Table 1. Molecular Devices’ ScanLater Western Blot Detection Cartridge uses TRF detection to turn its SpectraMax i3X and Paradigm plate readers into Western blot readers. The SpectraMax ABS readers use a grating monochromator to select the exact wavelength needed for every assay. Controls containing all reaction components with either DI water or a fluorescent standard in place of the fluorescent substrate were run alongside the experimental samples. User-upgradeable detection modules allow you to expand the capabilities of your microplate reader when your research requires it. For more detailed information and technical support of Molecular Devices instruments or software,The SpectraMax® Paradigm Multi- Mode Microplate Reader with Tunable Wavelength (TUNE) Detection Cartridge from Molecular Devices combines the flexibility of wavelength scanning with the high sensitivity of filters. 660-665 Eskdale Road. Also refer to this Multimode Reader Comparison Chart. The SpectraMax i3 Multi-Mode Detection Platform is a versatile instrument that can perform various assays and measurements on microplates and cuvettes. Molecular Devices are known for both the reliability and the wide uses of their products. 在SpectraMax i3x和SpectraMax iD5微孔板读板机上使用 SoftMax Pro软件绘制标准曲线,并进行4参数曲线拟合(图 4),结果见表2。使用EC50评估该测定方法的适用性,EC50值 应低于150 nM。对于两个读板机,EC 50值均低于85 nM,处 于可接受范围内。Cisbio将可接受的信噪比定义为≥. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. The fluorescence quantum yield (QY) of the Pdots was measured by a UV−NIR absolute PL QY. The reader can be equipped with a NanoBRET detection for a 4-fold improvement in limit of. The SpectraMax® i3x Multi-Mode Microplate Reader measures absorbance, fluorescence, and luminescence with available upgrades including western blot, cell imaging, and fast kinetics with injectors plus additional detection modes. The SpectraMax i3x reader measures spectral-based absorbance, fluorescence, and luminescence with the added functionality of modular upgrades for western blot, imaging, and fast kinetics with injectors. Thetypeof luciferase(Renilla. Fluorescence was measured using a microplate fluorometer (SpectraMax i3x, Molecular Devices, Beckman Coulter, CA, USA) with 365 nm excitation and 450 nm emission filters. SoftMax Pro GxP software is a special release that includ es full user and permission control and audit trail generation in addition to all the dataBased on the SpectraMax i3x system, ACROBiosystems provides biomedical research and development services for customers seeking quantification and detection of antibodies-antigen interaction. Videos & Webinars. The assay can accurately test the toxicology of compounds as shown in Figure 1. Multimode Readers Comparison Chart. Art-science interactive light show/animation. The SpectraMax® 190 spectrophotometer is ideal for most life science applications, especially DNA analysis. Published Dec 16, 2020 | Updated Dec 16, 2020. SpectraMax i3x Multi-Mode Detection Platform. DNA/RNA concentration is commonly estimated by dividing the A260 value by the 1-cm absorptivity value (or multiplying by its reciprocal). 5014038F 3 Contents SafetyInformation 5 Warnings,Cautions,Notes,andTips 5 Chapter1:Introduction 11 ComputerIntegration 11 Applications 12 DualPhotomultiplierTubes 12,相关视频:多功能酶标仪SpectraMax i3x的维护操作-注射器卡盒,多功能酶标仪SpectraMax iD5的维护操作-注射器卡盒,多功能酶标仪SpectraMax i3x的维护操作-卡盒的安装和拆卸,细胞计数及活率分析仪 Vi-CELL BLU 功能&操作讲解,CRISPR基因编辑系统介绍:Cas9和Cas12a,流式. SpectraMax i3, i3x, and iD5 readers. TNF-alpha quantification down to low picomolar levels on the SpectraMax Paradigm Platform. 2. Note: Additional readers with similar performance are listed. UV-Vis absorbance, fluorescence and luminescence • Accommodates plate types from six to 384-well format • Easily upgradeable with interchangeable filter cubesSpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. 304 signal level saturation. Absorbance was measured on the SpectraMax i3x Multi-Mode Platform at 475 nm and 660 nm after 1-4 hours of incubation. 3, were mixed in a final volume of 100 μL in 10 mM sodium phosphate buffer, pH 7.